SIMPLEX ? One (1) Zoeller Model 6189; 230 volt 1 phase Commercial duty pump with 1.5? Vertical discharge, 2 hp oil filled motor (17.01 FLA per pump ), cast iron vortex, stainless steel shaft with tandem mechanical seals, cast iron motor housing with cast iron volute, 25 foot power cord; pump capable of passing 3/4? solids. Design Point: 65 GPM at 65? TDH. ? (1) 2? Flanged cast iron Plug valve.. One (1) 2? Union. Valves shipped loose for installation in the field ? One (1) 1.5x2? guide rail assemblies consisting of base elbow, quick disconnect slide assemblies, and upper bracket factory installed. ? One (1) UL Listed 115, 200, 230 volt control panel the following features: o o Painted steel back panel and aluminum inner door o Incoming power block o Motor circuit breakers o Control circuit breaker o IEC rated starters o Control transformer o Hand-off-auto selector switches o Run lights o Seal fail lights and relays o Heat sensor lights and relays o Power on light o Lightning arrestor o Phase monitor o All lights to be 22mm o Alarm test switch o Required control relays o Terminal strip and ground lugs o UL listed and labeled 698A o Alarm light and horn with silence circuitry o Elapsed time meters o Lag pump time delay o Dry contacts-High level, pump fail from overload/overtemp, and seal fail o Includes three (3) 25? weighted, normally open mechanical float switches.

Special Order Products
831774
Requires Quote

SIMPLEX ? One (1) Zoeller Model 6189; 230 volt 1 phase Commercial duty pump with 1.5? Vertical discharge, 2 hp oil filled motor (17.01 FLA per pump ), cast iron vortex, stainless steel shaft with tandem mechanical seals, cast iron motor housing with cast iron volute, 25 foot power cord; pump capable of passing 3/4? solids. Design Point: 65 GPM at 65? TDH. ? (1) 2? Flanged cast iron Plug valve.. One (1) 2? Union. Valves shipped loose for installation in the field ? One (1) 1.5x2? guide rail assemblies consisting of base elbow, quick disconnect slide assemblies, and upper bracket factory installed. ? One (1) UL Listed 115, 200, 230 volt control panel the following features: o o Painted steel back panel and aluminum inner door o Incoming power block o Motor circuit breakers o Control circuit breaker o IEC rated starters o Control transformer o Hand-off-auto selector switches o Run lights o Seal fail lights and relays o Heat sensor lights and relays o Power on light o Lightning arrestor o Phase monitor o All lights to be 22mm o Alarm test switch o Required control relays o Terminal strip and ground lugs o UL listed and labeled 698A o Alarm light and horn with silence circuitry o Elapsed time meters o Lag pump time delay o Dry contacts-High level, pump fail from overload/overtemp, and seal fail o Includes three (3) 25? weighted, normally open mechanical float switches.

QTY